How long will the Anker SOLIX F3800 Plus run a fridge, CPAP or sump pump?

3,840 Wh, 6,000 W AC output, 9,000 W surge. After conversion losses about 3,264 Wh reaches your appliances. Every figure below is worked out from Anker SOLIX's published specs and the sourced appliance data on Methods.

Last updatedOct 18, 2026

Specs and priceAnker SOLIX US store, read Oct 18, 2026: $2,599.99 (list $2,999.99)

The short answer

Try your own list: runtime calculator with the F3800 Plus · outage sizing · charge time · solar recharge

Runtime for common appliances

Hours = 3,840 Wh × 100% usable × 85% efficiency ÷ (the appliance's watts), one appliance at a time, from full. Basis: Jackery's published 0.85 runtime factor; 100% of capacity usable (the station's own cutoff), an example since the maker doesn't publish it. The output check compares the station's 6,000 W output with the appliance's peak running draw (a fridge's defrost heater counts) and its 9,000 W surge with the start-up draw.

Anker SOLIX F3800 Plus against 16 appliances
ApplianceWatts usedRuns forPeak running, WStart-up, WOutput check
Refrigerator, top freezerENERGY STAR certified-product data (data.energystar.gov)41.4average, compressor cycling included79 h (3.3 days)425320Runs it
Refrigerator, bottom freezerENERGY STAR certified-product data (data.energystar.gov)64.6average, compressor cycling included51 h (2.1 days)425320Runs it
Refrigerator, side by sideENERGY STAR certified-product data (data.energystar.gov)73.1average, compressor cycling included44.7 h425320Runs it
Upright freezerENERGY STAR certified-product data (data.energystar.gov)50average, compressor cycling included65 h (2.7 days)425320Runs it
Chest freezerENERGY STAR certified-product data (data.energystar.gov)24.9average, compressor cycling included131 h (5.5 days)160320Runs it
Microwave ovenWhirlpool, Generator Usage with Appliances1,100running3 h1,1001,100Runs it
CPAP (ResMed AirSense 11) medicalResMed AirSense 11 user guide, technical specifications56.1average58 h (2.4 days)73.273.2Runs it
Oxygen concentrator (Philips EverFlo) medicalPhilips Respironics EverFlo brochure350running9.3 h350350Runs it
Sump pump, 3/10 HP (Zoeller M53)Zoeller Model M53 spec page1,116running2.9 h1,1163,347Runs it
Window AC, 8,000 BTUENERGY STAR certified-product data (data.energystar.gov)533running6.1 h5331,066Runs it
Space heater (Lasko 754200)Lasko 754200 product page1,500running2.2 h1,5001,500Runs it
Ceiling fan, 50 to 54 in, highENERGY STAR certified-product data (data.energystar.gov)28.6running114 h (4.8 days)28.628.6Runs it
TV, 55 inENERGY STAR certified-product data (data.energystar.gov)96.5running33.8 h96.596.5Runs it
Internet gateway (Xfinity XB8)CableLabs Energy Reporting, Comcast small network equipment17running192 h (8 days)1717Runs it
LED bulb, 60 W equivalent (Feit OM60DM)Feit Electric OM60DM/927CA product page8.8running371 h (15.5 days)8.88.8Runs it
Phone charger (Apple 20W USB-C)Apple 20W USB-C Power Adapter20running163 h (6.8 days)2020Runs it

Fridge and freezer hours use ENERGY STAR median yearly energy, which includes cycling and defrost. Microwave, heater and AC hours are for nonstop use. Refrigerator calculator for your own fridge's label.

CPAP nights

Medical equipment

A power station is not a medical backup system, and these are planning estimates. Ask your device maker or equipment supplier how to run your CPAP from battery power, and keep a plan for longer outages. What to check first.

Eight-hour nights at 10 cmH2O, through the AC outlet
AirSense setupDraw, WNights
No humidifier, SlimLine tubing11.236.6
Humidifier at 4, SlimLine tubing27.614.8
Humidifier at 8, SlimLine tubing43.99.3
Heated tube (ClimateLineAir at 30°C), no humidifier18.222.4
Heated tube and humidifier, both on Auto45.29
Heated tube at 30°C and humidifier at 8596.9
AirSense 11, typical (ResMed user guide)56.17.3

AirSense 10 draw is ResMed's battery-guide figure in amps at 12 V DC × 12 (ResMed battery guide). Nights = usable energy ÷ (draw) ÷ 8 hours. Other pressures and machines: CPAP calculator.

Sump pumps

Start-up allows 3 × running watts, the top of Whirlpool's two-to-three-times range for motors. The example storm pace is 6 cycles an hour of 15 seconds each; time your own pump during rain.

Anker SOLIX F3800 Plus against 5 sump pumps
PumpRunning, WStart-up, WPumping nonstopAt 6 cycles an hourCheck
Zoeller M53, 3/10 HP1,1163,3462.9 h117 h (4.9 days)Runs it
Zoeller M98, 1/2 HP1,0813,2433 h121 h (5 days)Runs it
Superior Pump 92341, 1/3 HP4921,4766.6 h265 h (11.1 days)Runs it
Wayne CDU790, 1/3 HP1,1403,4202.9 h115 h (4.8 days)Runs it
Wayne CDU980E, 3/4 HP1,1763,5282.8 h111 h (4.6 days)Runs it

Running watts are each pump's rated amps × volts, so they err high. Sump pump calculator.

Charge time and solar refill

Empty to full, from Anker SOLIX's published figures
MethodTimeMaker's figure
Wall outlet, standard2.9 h est.AC input 120 V, 15 A max; AC input power (charging) 1,800 W max
Wall outlet, fastest modenone listedNo faster mode listed
Car's 12 V socketnot listedCar charging input not listed

"est." = worked out from input watts × 0.74 (wall) or 0.89 (car), the medians makers' own watts-and-time figures imply. See Methods.

Days of sun to fill from empty with 3,200 W of panels (its solar limit)
StateWorst-month sun hoursDays, worst monthDays, year average
CaliforniaLos Angeles4.61 (Dec)0.30.3
TexasHouston3.76 (Dec)0.40.3
FloridaJacksonville4.23 (Dec)0.40.3
New YorkNew York City2.88 (Dec)0.50.4
ArizonaPhoenix5.43 (Dec)0.30.2
WashingtonSeattle1.59 (Dec)10.4

Into the battery per sun hour = 3,200 W × (1 − 14% losses) × 0.89 = 2,439 W. Sun hours: NREL (now NLR) PVWatts v8 for each state's largest city. All 50 states and DC: peak sun hours by state.