Can a power station run a gas furnace?

The gas makes the heat; the station only runs the blower, the inducer fan and the controls. Metered furnaces used about 300 to 600 W while firing at 60,000 Btu/h. The catch is the wiring: most furnaces are hard-wired.

Last updatedOct 18, 2026

Furnace electricityWisconsin field study of 31 furnaces (ACEEE, 2004) and Goodman's GR9S80 spec sheet, read Oct 18, 2026

Your furnace and station

Your furnace

Station

Result

0h

    The math

    Most furnaces are wired in on their own circuit, not plugged in; Goodman's sheet says to make the connections to the National Electrical Code. Running one from a station takes a transfer switch or inlet installed by an electrician.

    Every station against this furnace

    Hours from full at your firing share. Gray rows can't run or start it on paper. The shaded row is the smallest station in our table that runs it for your hours. Prices are what each maker's US store showed on Oct 18, 2026.

    Links marked “affiliate link” go through Awin to that maker’s US store (Jackery or BLUETTI); if you buy, the maker may pay us a commission at no cost to you. It never changes the hours, the checks or which row is shaded. Affiliate disclosure.

    Every station in our table against this load
    StationCapacity, WhRuns it forAC output, WSurge, WStore priceVerdict

    What furnaces drew in the field

    Watts while firing = kWh per therm × input ÷ 100,000 Btu per therm × 1,000
    Furnace typekWh per therm40,000 Btu/h60,000 Btu/h80,000 Btu/h100,000 Btu/hFan only, median W

    Medians from Pigg and Talerico's metering of 31 new Wisconsin furnaces (ACEEE Summer Study, 2004). Multi-stage ECM furnaces spend most of their time at low fire with a slower blower, which is why they use about half the electricity per therm. The study also found ECM furnaces used more than their rating data suggested in real homes, which it put down to higher static pressure in the ducts. Your furnace's age, filter and ductwork change these numbers.

    How the hours are worked out

    Watts while firing = the study's kWh per therm × your furnace's gas input in therms an hour (input ÷ 100,000 Btu per therm, EIA) × 1,000. Average draw = watts while firing × share of time it fires + the station's idle draw. Hours = capacity × share you can use × efficiency ÷ average draw. The output check uses the furnace's electrical rating, amps × volts, which is higher than what it draws; the start-up check multiplies that by the start-up multiple, at the low end of Whirlpool's range because the rating already errs high (Whirlpool). Sources are on Methods and sources.