Wattcellar

How long will the BLUETTI AC180 run a fridge, CPAP or sump pump?

1,152 Wh, 1,800 W AC output, 2,700 W surge. After conversion losses about 881 Wh reaches your appliances. Every figure below is worked out from BLUETTI's published specs and the sourced appliance data on Methods.

Last updatedOct 18, 2026

Specs and priceBLUETTI US store, read Oct 18, 2026: $499

The short answer

Try your own list: runtime calculator with the AC180 · outage sizing · charge time · solar recharge

Runtime for common appliances

Hours = 1,152 Wh × 90% usable × 85% efficiency ÷ (the appliance's watts + 15 W station idle draw), one appliance at a time, from full. Basis: BLUETTI EU AC180 article: DoD 90%, η 85%, self-consumption about 15 W. The output check compares the station's 1,800 W output with the appliance's peak running draw (a fridge's defrost heater counts) and its 2,700 W surge with the start-up draw.

BLUETTI AC180 against 16 appliances
ApplianceWatts usedRuns forPeak running, WStart-up, WOutput check
Refrigerator, top freezerENERGY STAR certified-product data (data.energystar.gov)41.4average, compressor cycling included15.6 h425320Runs it
Refrigerator, bottom freezerENERGY STAR certified-product data (data.energystar.gov)64.6average, compressor cycling included11.1 h425320Runs it
Refrigerator, side by sideENERGY STAR certified-product data (data.energystar.gov)73.1average, compressor cycling included10 h425320Runs it
Upright freezerENERGY STAR certified-product data (data.energystar.gov)50average, compressor cycling included13.6 h425320Runs it
Chest freezerENERGY STAR certified-product data (data.energystar.gov)24.9average, compressor cycling included22.1 h160320Runs it
Microwave ovenWhirlpool, Generator Usage with Appliances1,100running47 min1,1001,100Runs it
CPAP (ResMed AirSense 11) medicalResMed AirSense 11 user guide, technical specifications56.1average12.4 h73.273.2Runs it
Oxygen concentrator (Philips EverFlo) medicalPhilips Respironics EverFlo brochure350running2.4 h350350Runs it
Sump pump, 3/10 HP (Zoeller M53)Zoeller Model M53 spec page1,116running—1,1163,347May not start: needs 3,347 W
Window AC, 8,000 BTUENERGY STAR certified-product data (data.energystar.gov)533running1.6 h5331,066Runs it
Space heater (Lasko 754200)Lasko 754200 product page1,500running35 min1,5001,500Runs it
Ceiling fan, 50 to 54 in, highENERGY STAR certified-product data (data.energystar.gov)28.6running20.2 h28.628.6Runs it
TV, 55 inENERGY STAR certified-product data (data.energystar.gov)96.5running7.9 h96.596.5Runs it
Internet gateway (Xfinity XB8)CableLabs Energy Reporting, Comcast small network equipment17running27.5 h1717Runs it
LED bulb, 60 W equivalent (Feit OM60DM)Feit Electric OM60DM/927CA product page8.8running37 h8.88.8Runs it
Phone charger (Apple 20W USB-C)Apple 20W USB-C Power Adapter20running25.2 h2020Runs it

Fridge and freezer hours use ENERGY STAR median yearly energy, which includes cycling and defrost. Microwave, heater and AC hours are for nonstop use. Refrigerator calculator for your own fridge's label.

CPAP nights

Medical equipment

A power station is not a medical backup system, and these are planning estimates. Ask your device maker or equipment supplier how to run your CPAP from battery power, and keep a plan for longer outages. What to check first.

Eight-hour nights at 10 cmH2O, through the AC outlet
AirSense setupDraw, WNights
No humidifier, SlimLine tubing11.24.2
Humidifier at 4, SlimLine tubing27.62.6
Humidifier at 8, SlimLine tubing43.91.9
Heated tube (ClimateLineAir at 30°C), no humidifier18.23.3
Heated tube and humidifier, both on Auto45.21.8
Heated tube at 30°C and humidifier at 8591.5
AirSense 11, typical (ResMed user guide)56.11.5

AirSense 10 draw is ResMed's battery-guide figure in amps at 12 V DC × 12 (ResMed battery guide). Nights = usable energy ÷ (draw + 15 W idle) ÷ 8 hours. Other pressures and machines: CPAP calculator.

Sump pumps

Start-up allows 3 × running watts, the top of Whirlpool's two-to-three-times range for motors. The example storm pace is 6 cycles an hour of 15 seconds each; time your own pump during rain.

BLUETTI AC180 against 5 sump pumps
PumpRunning, WStart-up, WPumping nonstopAt 6 cycles an hourCheck
Zoeller M53, 3/10 HP1,1163,346——May not start: needs 3,346 W
Zoeller M98, 1/2 HP1,0813,243——May not start: needs 3,243 W
Superior Pump 92341, 1/3 HP4921,4761.8 h32.3 hRuns it
Wayne CDU790, 1/3 HP1,1403,420——May not start: needs 3,420 W
Wayne CDU980E, 3/4 HP1,1763,528——May not start: needs 3,528 W

Running watts are each pump's rated amps × volts, so they err high. Sump pump calculator.

Charge time and solar refill

Empty to full, from BLUETTI's published figures
MethodTimeMaker's figure
Wall outlet, standard1.7 hStandard mode about 1,000 W, 1.7 hours (1.7–2.2); Turbo about 1,440 W, 1.3 hours (1.3–1.8)
Wall outlet, fastest mode1.3 hTurbo mode (app)
Car's 12 V socketnot listedCar input 12/24 V from a cigarette lighter port; watts not listed

"est." = worked out from input watts × 0.74 (wall) or 0.89 (car), the medians makers' own watts-and-time figures imply. See Methods.

Days of sun to fill from empty with 500 W of panels (its solar limit)
StateWorst-month sun hoursDays, worst monthDays, year average
CaliforniaLos Angeles4.61 (Dec)0.70.5
TexasHouston3.76 (Dec)0.80.6
FloridaJacksonville4.23 (Dec)0.70.6
New YorkNew York City2.88 (Dec)10.7
ArizonaPhoenix5.43 (Dec)0.60.5
WashingtonSeattle1.59 (Dec)1.90.8

Into the battery per sun hour = 500 W × (1 − 14% losses) × 0.89 = 381 W. Sun hours: NREL (now NLR) PVWatts v8 for each state's largest city. All 50 states and DC: peak sun hours by state.

Compare